Biology of Sport
pISSN 0860-021X    eISSN 2083-1862
Archival Issues
Volume 34, 2017
Volume 33, 2016
Volume 32, 2015
Volume 31, 2014
Volume 30, 2013
Volume 29, 2012
Volume 28, 2011
Volume 27, 2010
Volume 26, 2009
Volume 25, 2008
Volume 24, 2007
Volume 23, 2006
Volume 22, 2005
Volume 21, 2004
Volume 20, 2003
Archival Issues 1984-1998
Search
Newsletter
Information for Authors
Special Information
 » 
Journal Abstract
 
Reliability of the calculated maximal lactate steady state in amateur cyclists
Jennifer Adam, Matthias Oehmichen, Eva Oehmichen, Janine Rother, Ulrike Maria Müller, Thomas Hauser, Henry Schulz
Biol Sport 2015; 32(2):97-102
ICID: 1134311
Article type: Original article
IC™ Value: 10.00
Abstract provided by Publisher
 
Complex performance diagnostics in sports medicine should contain maximal aerobic and maximal anaerobic performance. The requirements on appropriate stress protocols are high. To validate a test protocol quality criteria like objectivity and reliability are necessary. Therefore, the present study was performed in intention to analyze the reliability of maximal lactate production rate (VLamax) by using a sprint test, maximum oxygen consumption (VO2max) by using a ramp test and, based on these data, resulting power in calculated maximum lactate-steady-state (PMLSS) especially for amateur cyclists. All subjects (n=23, age 26 ± 4 years) were leisure cyclists. At three different days they completed first a sprint test to approximate VLamax. After 60 min of recreation time a ramp test to assess VO2max was performed. The results of VLamax-test and VO2max-test and the body weight were used to calculate PMLSS for all subjects. The intra class correlation (ICC) for VLamax and VO2max was 0.904 and 0.987, respectively, coefficient of variation (CV) was 6.3 % and 2.1 %, respectively. Between the measurements the reliable change index of 0.11 mmol∙l-1∙s-1 for VLamax and 3.3 ml∙kg-1∙min-1 for VO2max achieved significance. The mean of the calculated PMLSS was 237 ± 72 W with an RCI of 9 W and reached with ICC = 0.985 a very high reliability. Both metabolic performance tests and the calculated PMLSS are reliable for leisure cyclists

ICID 1134311

DOI 10.5604/20831862.1134311
 
FULL TEXT 435 KB


Related articles
  • in IndexCopernicus™
         maximum oxygen consumption [0 related records]
         maximal lactate-steady-state [0 related records]
         maximal lactate production rate [0 related records]


  •  

    Copyright © Biology of Sport  2017
    Page created by Index Copernicus Ltd. All Rights reserved.