Total body composition estimated by standing-posture 8-electrode bioelectrical impedance analysis in male wrestlers
Ming-fang Cheng, Yu-Yawn Chen, Tsong-Rong Jang, Wen-Lang Lin, Jae Chen, Kuen-Chang Hsieh
Biol Sport 2016; 33(4):399-405
ICID: 1224097
Article type: Original article
IC™ Value: 10.00
Abstract provided by Publisher
 
Standing-posture 8-electrode bioelectrical impedance analysis is a fast and practical method for evaluating body composition in clinical settings, which can be used to estimate percentage body fat (BF%) and skeletal muscle mass in a subject’s total body and body segments. In this study, dual-energy X-ray absorptiometry (DXA) was used as a reference method for validating the standing 8-electrode bioelectrical impedance analysis device BC-418 (BIA8, Tanita Corp., Tokyo, Japan). Forty-eight Taiwanese male wrestlers aged from 17.9 to 22.3 years volunteered to participate in this study. The lean soft tissue (LST) and BF% in the total body and body segments were measured in each subject by the BIA8 and DXA. The correlation coefficients between total body, arm, leg segments impedance index (BI, ht2/Z) and lean soft tissue mass measured from DXA were r = 0.902, 0.453, 0.885, respectively (p < 0.01). In addition, the total body and segmental LST estimated by the BIA8 were highly correlated with the DXA data (r = 0.936, 0.466, 0.886, p < 0.01). The estimation of total body and segmental BF% measured by BIA8 and DXA also showed a significant correlation (r > 0.820, p < 0.01). The estimated LST and BF% from BIA8 in the total body and body segments were highly correlated with the DXA results, which indicated that the standing-posture 8-electrode bioelectrical impedance analysis may be used to derive reference measures of LST and BF% in Taiwanese male wrestlers.

ICID 1224097

DOI 10.5604/20831862.1224097
 
FULL TEXT 484 KB


Related articles
  • in IndexCopernicus™
         bioimpedance index [0 related records]
         Body Composition [518 related records]
         Dual energy X-ray absorptiometry [0 related records]
         Appendicular [0 related records]


  •  

    Copyright © Biology of Sport  2017
    Page created by Index Copernicus Ltd. All Rights reserved.